Function library

FCODE (free codes)

12

l

309

EDBCSXS064 EN 4.0

12.22

FCODE (free codes)

Function

This function block provides different signals. The signals can be directly read out and
processed via the assigned "free" codes of the controller.

ƒ

Values in the codes of the function block are assigned to the corresponding output
signals.

ƒ

The code value is converted into a signal value via a fixed scaling routine.

C0017

C0141

C0109/1

C0108/2

C0037

C0108/1

C0135

C0109/2

rpm TO INT

rpm TO INT

DWORD

TO

BIT/BOOL

C0471

C0472/1

C0473/1

C0474/1

C0472/20

C0473/10

C0474/5

BOOL

C0250

DINT

C0475/1

C0475/2

% TO INT

% TO INT

INT

INT

FCODE

16 Bit

...

...

...

...

...

38

43

44

45

46

47

48

271

272

303

49

68

69

78

16

20

79

80

304

319

FCODE-C0017

FCODE-C0037

FCODE-C0141

FCODE-C0108/1

FCODE-C0108/2

FCODE-C0109/2

FCODE-C0135.Bit0

FCODE-C0109/1

FCODE-C0471.Bit0

FCODE-C0471.Bit31

FCODE-C0250

FCODE-C0472/1

FCODE-C0472/20

FCODE-C0473/1

FCODE-C0473/10

FCODE-C0475/2_v

FCODE-C0135.Bit15

FCODE-C0474/1

FCODE-C0474/5

FCODE-C0475/1_v

ECSXA261

Fig. 12−23

FCODE function block

Beispiel

You can enter a percentage value [%] in C0472/1 (e.g. by using the keypad). The value is
directly assigned to the signal "FCODE−C0472/1" (data type "integer") via a fixed scaling
routine and can be processed in the PLC program.

)

Note!

The free code C0470 has the same memory address as C0471. C0470 can be
read out via the signals "FCODE−C0471.Bit0 ... 31" in C0471.
In contrast to code C0471 which can accept a 32−bit value, code C0470 is
divided into four subcodes with eight bits each.