Function library

Speed (speed control)

Setpoint processing

12

l

327

EDBCSXS064 EN 4.0

12.27.2.2

Setting acceleration and deceleration times

The speed setpoint is led via a ramp function generator. This enables input steps to be
converted into a ramp.

The acceleration time (T

ir

) and deceleration time (T

if

)

refer to a change in speed from "0"

to n

max

(0 ... 100%). The times to be set are calculated according to the formulae:

Acceleration time (code C0012)

Deceleration time (code C0013)

T

ir

+ t

ir

@ 100 %

w2

* w1

T

if

+ t

if

@ 100 %

w2

* w1

[%]

w2

100

w1

0

t

ir

t

if

T

ir

T

if

t

RFG-OUT

ECSXASA001

Fig. 12−30

Diagram for acceleration and deceleration time

In C0101/1 ... 15 and C0103/1 ... 15, 15 time pairs (T

i

times) can be stored additionally. Via

the inputs SPEED−NSET.TIx (C7411/13 ... C7411/16) the T

i

times can be activated:

Signal name

Source for active time pair

SPEED−NSET.TI8

SPEED−NSET.TI4

SPEED−NSET.TI2

SPEED−NSET.TI1

Acceleration

time

Deceleration

time

0

0

0

0

C0012

C0013

0

0

0

1

C0101/1

C0103/1

0

0

1

0

C0101/2

C0103/2

0

0

1

1

C0101/3

C0103/3

0

1

0

0

C0101/4

C0103/4

0

1

0

1

C0101/5

C0103/5

0

1

1

0

C0101/6

C0103/6

0

1

1

1

C0101/7

C0103/7

1

0

0

0

C0101/8

C0103/8

1

0

0

1

C0101/9

C0103/9

1

0

1

0

C0101/10

C0103/10

1

0

1

1

C0101/11

C0103/11

1

1

0

0

C0101/12

C0103/12

1

1

0

1

C0101/13

C0103/13

1

1

1

0

C0101/14

C0103/14

1

1

1

1

C0101/15

C0103/15

Advertising
This manual is related to the following products: