Code table

13

l

408

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C2485 MONIT CE15

3

Fault response − gate function
monitoring (CE15)
"Timeout" when remote
parameterisation (C0370) is
activated via interface X14
(CAN−AUX)

^ 198

^ 190

0

TRIP

2

Warning

3

Off

C2491

Process data input words
(hexadecimal) for CAN bus
interface X14
Hexadecimal value is bit−coded.
Read only

1 CANa IN bits

0

{1 hex}

FFFF CANaux1_IN (bit 0 ... 15)

2 CANa IN bits

CANaux1_IN (bit 16 ... 31)

3 CANa IN bits

CANaux2_IN (bit 0 ... 15)

4 CANa IN bits

CANaux2_IN (bit 16 ... 31)

5 CANa IN bits

CANaux3_IN (bit 0 ... 15)

6 CANa IN bits

CANaux3_IN (bit 16 ... 31)

C2492

Process data input words
(decimal) for CAN bus interface
X14
100.00% = 16384
Read only

1 CANa IN

words

−199.99

{0.01 %}

199.99 CANaux1_IN word 1

2 CANa IN

words

CANaux1_IN word 2

3 CANa IN

words

CANaux1_IN word 3

4 CANa IN

words

CANaux2_IN word 1

5 CANa IN

words

CANaux2_IN word 2

6 CANa IN

words

CANaux2_IN word 3

7 CANa IN

words

CANaux2_IN word 4

8 CANa IN

words

CANaux3_IN word 1

9 CANa IN

words

CANaux3_IN word 2

10 CANa IN

words

CANaux3_IN word 3

11 CANa IN

words

CANaux3_IN word 4