Speed (speed control)

12

l

322

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

20 Speed−dig

Inversion of additional torque
setpoint (SPEED−MAddInv)

[C7411]

Selection of the signal source for
the digital input signals of the
"Speed" function block

1 SpeedIn−dig

1000

0 (FALSE, not assigned)

CW rotation (SPEED−RLQ.Cw)

^ 325

2 SpeedIn−dig

1000

0 (FALSE, not assigned)

CCW rotation (SPEED−RLQ.CCw)

3 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the fixed speeds
(SPEED−NSET.Jog1) saved in
C0039

^ 326

4 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the fixed speeds
(SPEED−NSET.Jog2)saved in
C0039

5 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the fixed speeds
(SPEED−NSET.Jog4)saved in
C0039

6 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the fixed speeds
(SPEED−NSET.Jog8)saved in
C0039

7 SpeedIn−dig

1000

0 (FALSE, not assigned)

Setting of the speed setpoint
integrator to 0 along the
adjusted ramps
(SPEED−NSET.Rfg0)

^ 326

8 SpeedIn−dig

1000

0 (FALSE, not assigned)

Inversion of additional speed
setpoint (SPEED−NAddInv)

9 SpeedIn−dig

1000

0 (FALSE, not assigned)

Keeping (freezing) the speed
setpoint integrator to the actual
value (SPEED-NSET.RfgStop)

10 SpeedIn−dig

1000

0 (FALSE, not assigned)

Activation of the motor holding
brake (SPEED−BRK.SetBrake)

^ 340

11 SpeedIn−dig

1000

0 (FALSE, not assigned)

Switching of speed − torque
(SPEED−MCTRL.NMSwt)

^ 332

12 SpeedIn−dig

1000

0 (FALSE, not assigned)

Source for the integral−action
component of the speed
controller (SPEED−MCTRL.ILoad)

13 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI1)

^ 326

14 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI2)

15 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI4)

16 SpeedIn−dig

1000

0 (FALSE, not assigned)

Selection of the acceleration and
deceleration times stored in
C0101 and C0103
(SPEED−NSET.TI8)

17 SpeedIn−dig

1000

0 (FALSE, not assigned)

Setting of quick stop
(SPEED−QSP.Set1)

^ 332

18 SpeedIn−dig

1000

0 (FALSE, not assigned)

Setting of quick stop
(SPEED−QSP.Set2)

19 SpeedIn−dig

1000

0 (FALSE, not assigned)

Activation of phase controller
(SPEED-MCTRL.PosOn)