Electrical installation

Wiring of the feedback system

Encoder connection

5

l

89

EDBCSXS064 EN 4.0

Incremental encoder (TTL encoder)

Features

Input/output frequency:

0 ... 200 kHz

Current consumption:

6 mA per channel

Current on output V

CC

(X8/pin 4):

Max. 200 mA

X8

5

1

9

6

B

V

CC

GND

Z

R1 (+KTY)

R2 (-KTY)

1

2

3

4

5

6

7

8

9

A

< 50 m

A

A

A

B

Z

B

B

Z

Z

KTY



ECSXA026

Fig. 5−19

Connection of incremental encoder with TTL level (RS−422)

 Signals in case of clockwise rotation

Cores twisted in pairs

Assignment of plug connector X8: Sub−D 9−pole

Pin

1

2

3

4

5

6

7

8

9

Signal

B

A

A

V

CC

GND

(R1/+KTY)

Z

Z

R2

(−KTY)

B

0.14 mm

2

(AWG 26)

1 mm

2

(AWG 18)

0.14 mm

2

(AWG 26)

Advertising