Function library

CAN1In

12

l

275

EDBCSXS064 EN 4.0

User data

Each of the eight bytes of received user data is assigned to different signal types. For this
reason, they can be evaluated —as required— as

ƒ

digital signals (1 bit)

ƒ

control word / analog signals (16 bits)

ƒ

phase signals (32 Bit)

in the axis module:

Byte

Digital signals (1 bit)

Analog signals (16 bit)

Phase signals (32 Bit)

1, 2

CAN1In−Ctrl.Bit0
CAN1In−Ctrl.Bit1
CAN1In−Ctrl.Bit2

CAN1In−Ctrl.Quickstop_B3

CAN1In−Ctrl.Bit4

...

CAN1In−Ctrl.Bit7

CAN1In−Ctrl.Disable_B8

CAN1In−Ctrl.CInhibit_B9

CAN1In−Ctrl.TripSet_B10

CAN1In−Ctrl.TripReset_B11

CAN1In−Ctrl.Bit12

...

CAN1In−Ctrl.Bit15

CAN1In−DctrlCtrl

CAN1In−W0/W1

Note:
The internal control word is firmly allocated to bytes 1 and 2. Via this
control word it is possible touse

l

signals for the functions "quick stop" (QSP), DISABLE, CINH,
TRIP−SET und TRIP−RESET and

l

the other 11 control bits (CAN1In−Ctrl.Bit...)

in further functions/function blocks.

3, 4

CAN1In−W1.Bit0

...

CAN1In−W1.Bit15

CAN1In−W1

5, 6

CAN1In−Bit0

...

CAN1In−Bit15

CAN1In−W2

CAN1In−W2/W3

7, 8

CAN1In−Bit16

...

CAN1In−Bit31

CAN1In−W3

)

Note!

Via C0357 you can set the monitoring time (Lenze setting: 3000 ms) for data
reception. (

198)