Commissioning – Lenze ECSCSxxx User Manual

Page 111

Advertising
background image

Commissioning

Setting of the feedback system for position and speed control

TTL/SinCos encoder as position encoder and resolver as speed encoder

6

l

111

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0414 DIS: ResQual.

Resolver modulation
Quality of the resolver excitation
amplitude set under C0416
(recommendation: 0.5 ... 1.2;
ideal 1.0)

^ 104

0.00

{0.01}

1,60

[C0416] Resolver adj.

5

Resolver excitation amplitude

^ 104

0

100 %

1

80 %

2

68 %

3

58 %

4

50 %

5

45 %

6

40 %

7

37 %

[C0417] Resolver cor.

0

Resolver adjustment

^ 160

0

Ready

1

Start adjustment

2

Loading default values

[C0419] Enc. setup

110

Encoder selection

l

Selection of encoder type
indicated on the nameplate of
the Lenze motor.

l

The encoder data (C0420,
C0421, C0427) is set
automatically in accordance
with the selection.

^ 301

^ 106

^ 113

0

Common

110

IT512−5V

Incremental encoder with TTL
level

111

IT1024−5V

112

IT2048−5V

113

IT4096−5V

210

IS512−5V

SinCos encoder

211

IS1024−5V

212

IS2048−5V

213

IS4096−5V

307

AS64−8V

SinCos absolute value encoder
with Hiperface® interface
(single−turn)
Selections 307, 308, 309 are only
possible with operating system
7.0 or higher.

308

AS128−8V

309

AS256−8V

310

AS512−8V

311

AS1024−8V

407

AM64−8V

SinCos absolute value encoder
with Hiperface® interface
(multi−turn)
Selections 407, 408, 409 are only
possible with operating system
7.0 or higher.

408

AM128−8V

409

AM256−8V

410

AM512−8V

411

AM1024−8V