Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C7130

Display of the analog input
signals in the InNeg function
block (signal inversion)

^ 313

−32768
(= −199.9 %)

{1}

32767

(= 199.9 %)

1 InNeg−AnV

InNeg−AnIn1

2 InNeg−AnV

InNeg−AnIn2

C7131

Selection of the analog input
signals for the InNeg function
block (signal inversion)

^ 313

1 InNeg−An

1000

FIXED 0 % (not assigned)

Source for InNeg−AnIn1

2 InNeg−An

1000

FIXED 0 % (not assigned)

Source for InNeg−AnIn2

For possible signals see "selection list − analog
signals"

^ 437

C7150

Display of the phase input
signals in the InNeg function
block (signal inversion)

^ 313

−2147483647

{1}

2147483647

1 InNeg−PhiV

InNeg−PhiIn1

2 InNeg−PhiV

InNeg−PhiIn2

C7151

Selection of the phase input
signals for the InNeg function
block (signal inversion)

^ 313

1 InNeg−Phi

1000

FIXED 0 (not assigned)

Source for InNeg−PhiIn1

2 InNeg−Phi

1000

FIXED 0 (not assigned)

Source for InNeg−PhiIn2

For possible signals see "selection list − phase
signals"

^ 440