Function library

AIF1In

12

l

250

EDBCSXS064 EN 4.0

User data

Each of the eight bytes of received user data is assigned to different signal types. For this
reason, they can be evaluated —as required— as

ƒ

digital signals (1 bit)

ƒ

control word / analog signals (16 bits)

ƒ

phase signals (32 Bit)

in the axis module:

Byte

Digital signals (1 bit)

Analog signals (16 bit)

Phase signals (32 Bit)

1, 2

AIF1In−Ctrl.Bit0
AIF1In−Ctrl.Bit1
AIF1In−Ctrl.Bit2

AIF1In−Ctrl.Quickstop_B3

AIF1In−Ctrl.Bit4

...

AIF1In−Ctrl.Bit7

AIF1In−Ctrl.Disable_B8

AIF1In−Ctrl.CInhibit_B9

AIF1In−Ctrl.TripSet_B10

AIF1In−Ctrl.TripReset_B11

AIF1In−Ctrl.Bit12

...

AIF1In−Ctrl.Bit15

AIF1In−DctrlCtrl

AIF1In−W0/W1

Note:
The internal control word is firmly allocated to bytes 1 and 2. Via this
control word it is possible touse

l

signals for the functions "quick stop" (QSP), DISABLE, CINH,
TRIP−SET und TRIP−RESET and

l

the other 11 control bits (AIF1In−Ctrl.Bit...)

in further functions/function blocks.

3, 4

AIF1In−W1.Bit0

...

AIF1In−W1.Bit15

AIF1In−W1

5, 6

AIF1In−Bit0

...

AIF1In−Bit15

AIF1In−W2

AIF1In−W2/W3

7, 8

AIF1In−Bit16

...

AIF1In−Bit31

AIF1In−W3