21 digout (freely assignable digital outputs), Function library, Digout (freely assignable digital outputs) – Lenze ECSCSxxx User Manual

Page 308: Codes

Advertising
background image

Function library

DigOut (freely assignable digital outputs)

12

l

308

EDBCSXS064 EN 4.0

12.21

DigOut (freely assignable digital outputs)

Function

This function block conditions the digital signal "DigOut−Out1" and outputs it via X6/DO1.

ƒ

A motor holding brake supplied with low voltage via X6/B+ and X6/B− can be
connected to X25/B1 and X25/B2 62
– The motor holding brake can be switched by the signal DigOut−Relay .
– The terminal polarity for the outputs X6/DO1, X25/B1 and X25/B2 can be

configured via C0118.

ƒ

X6/SO serves to return information concerning the safety function "safe torque off"
(

^ 71).

Outputs_DIGITAL

X6

X6

1

0

C0118/1

DO1

SO

1

B-

B2

B+

1

0

C0118/2

1

B1

X25

X6

safe torque off

C0444/1

C0444/2

C0602

MONIT-Rel1

DIGOUT_bOut1_b

DIGOUT_bRelais_b

ECSXA242

Fig. 12−22

DigOut function block

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0118

Polarity of the digital outputs

^ 308

^ 121

1 DIGOUT pol

0

HIGH level active

X6/DO1 (DIGOUT_bOut1_b)

2 DIGOUT pol

0

HIGH level active

X25 (DIGOUT_bRelais_b, brake
connection)

0

HIGH level active

1

LOW level active

C6370

Display of the output signals at
the digital output and the brake
relay

^ 308

0 (= FALSE)

1 (= TRUE)

1 DIGOUT

Output signal at the digital
output X6/DO1 (DigOut−Out1)

2 DIGOUT

Control of the brake relay
(DigOut relay)

[C6371]

Selection of the digital output
signals for the digital output and
the brake relay

^ 308

1 DigoutIn−dig

1000

0 (FALSE, not assigned)

Source for the output signal at
the digital output X6/DO1
(DigOut−Out1)

2 DigoutIn−dig

1000

0 (FALSE, not assigned)

Source for the control of the
brake relay (DigOut relay)

For possible signals see "selection list − digital
signals"

^ 428

Advertising