OutNeg

Function

This function block serves to invert the output signals. The function block can invert digital,
analog and phase signals.

ƒ

The values of the analog signals are in a decimal range of ±32767.

ƒ

The values of the phase signals are in a decimal range of ±2147483648.

The values are calculated before the selected main function block is calculated. Thus the
calculated values are made available to the subsequent blocks in the current cycle.

OutNeg

C7230/1

32767

-32767

-1

C7230/2

32767

-32767

-1

C7250/1

2147483647

-2147483647

-1

C7210/1

-1

C7210/2

-1

C7210/3

-1

C7250/2

2147483647

-2147483647

-1

C7231/1

C7231/2

C7211/1

C7211/2

C7211/3

C7251/1

C7251/2

671

672

671

672

673

671

672

OutNeg-AnIn1

OutNeg-AnIn2

OutNeg-PhiIn1

OutNeg-DigIn1

OutNeg-DigIn2

OutNeg-DigIn3

OutNeg-PhiIn2

OutNeg-AnOut1

OutNeg-AnOut2

OutNeg-PhiOut1

OutNeg-DigOut1

OutNeg-DigOut2

OutNeg-DigOut3

OutNeg-PhiOut2

ECSXA252

Fig. 12−26

OutNeg function block

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C7210

Display of the digital input
signals in the OutNeg function
block (signal inversion)

^ 315

1 OutNeg−digV

OutNeg−DigIn1

2 OutNeg−digV

OutNeg−DigIn2

3 OutNeg−digV

OutNeg−DigIn3

C7211

Selection of the digital input
signals for the OutNeg function
block (signal inversion)

^ 315

1 OutNeg−dig

1000

0 (FALSE, not assigned)

Source for OutNeg−DigIn1

2 OutNeg−dig

1000

0 (FALSE, not assigned)

Source for OutNeg−DigIn2

3 OutNeg−dig

1000

0 (FALSE, not assigned)

Source for OutNeg−DigIn3

For possible signals see "selection list − digital
signals"

^ 428