Configuration

Remote parameterisation (gateway function)

8

l

190

EDBCSXS064 EN 4.0

8.5

Remote parameterisation (gateway function)

From operating system V6.x onwards, the axis module supports the remote
parameterisation of other fieldbus nodes. Then, all write/read accesses to parameters are
not executed anymore in the axis module but redirected to the bus node selected for
remote maintenance.

ƒ

The redirection takes place via the parameter data channel SDO1 of the selected
node.

ƒ

The node to which the write/read accesses is to be redirected, is determined with
the corresponding node address via C0370.
(C0370 = 0: remote parameterisation deactivated)

ƒ

With C0371 = 1, determine the interface X14 (CAN−AUX) of the axis module as
gateway channel.

ƒ

Use C2470 (CAN−AUX) to select the transmission channel for reading and writing
parameter data.

ƒ

A time−out during remote parameterisation activates the system error message
"CE15". The corresponding response can be configured under C2485 (

200).

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

[C0370] SDO gateway

0

Activate address
gateway/remote
parameterisation

l

C0370

¹ 0: All code

write/read accesses are
redirected to the CAN node
with the CAN node address
set here.

l

The corresponding code is
accessed via parameter data
channel 1 of the target device.

l

C0370 = 0: remote
parameterisation is
deactivated

^ 190

0

{1}

63

C0371 Gateway Ch.

1

Selection of the gateway channel

^ 190

0

CAN

Use CAN bus interface X4

1

CAN−AUX

Use CAN bus interface X14

C2470 ParWrite

0

CANaux channel used by
L_ParWrite/L_ParRead
(byComChannel = 11)

^ 190

0

Unused PDO channel free for
reconfiguration
(CANaux1...3_IN/CANaux1...3_OUT)

1

Parameter data channel 2