Code table

13

l

364

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0006] Op mode

1

Operating mode of the motor
control

l

If the master pulse (via
MCTRL: C0911 = 0 or DfIn:
C0428 = 0) is used, the
voltage supply has to be
switched off and then on
again when the operating
mode is changed.

l

Otherwise, the master pulses
will not be recognised.

1

Servo PM−SM

Servo control of synchronous
motors

2

Servo ASM

Servo control of asynchronous
motors

C0009 LECOM

address

1

Entry of the device address for
operation via AIF interface X1

1

{1}

99 Communication modules on AIF

interface X1:

l

LECOM−A/B/LI 2102

l

PROFIBUS−DP 2133

C0011 Nmax

3000

Maximum speed

500

{1 rpm}

16000 Reference value for the absolute

and relative setpoint selection
for the acceleration and
deceleration times.
For parameter setting via
interface: greater changes in one
step should only be made when
the controller is inhibited (CINH)!

C0012 TIR (ACC)

0.000

Acceleration time for the

l

speed setpoint (for "speed
control")

l

torque setpoint (for "torque
control")

^ 327

0.000

{0.001 s}

999.999 Relating to speed variation

0 rpm ... n

max

(C0011)

C0013 TIF (DEC)

0.000

Deceleration time for the

l

speed setpoint (for "speed
control")

l

torque setpoint (for "torque
control")

^ 327

0.000

{0.001 s}

999.999 Relating to speed variation

0 rpm ... n

max

(C0011)

C0017 FCODE (Qmin)

50

Free code for using speed signals
(Speed signal FCODE_nC17_a)

^ 309

−16000

{1 rpm}

16000

C0018 fchop

2

Switching frequency

1

4 kHz sin

4 kHz permanent PWM
frequency

2

8/4 kHz sin

8 kHz PWM frequency with
automatic derating to 4 kHz at
high load

C0019 Thresh nact =

0

0

Threshold when actual speed
value (n

act

) = 0 is detected.

(DCTRL_bNActEq0_b)

0

{1 rpm}

16000