Commissioning – Lenze ECSCSxxx User Manual

Page 146

Advertising
background image

Commissioning

Operation with motors from other manufacturers
Entering motor data manually

6

l

146

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0058 Rotor diff

−90.0

Rotor displacement angle (offset
angle)
Input in case of Lenze motor with

l

resolver: −90°

l

hiperface absolute value
encoder: 0°

Code value is adapted by the
rotor position adjustment
function (C0095).
Only relevant for the operation
of synchronous motors.

^ 151

−180.0

{0.1

_}

179.9

[C0080] Res pole no.

1

Number of pole pairs of resolver

1

{1}

10

[C0081] Mot power

3.20

Rated motor power according to
nameplate

0.01

{0.01 kW}

500.00

[C0084] Mot Rs

1.10

Stator resistance of the motor
The upper limit is
device−dependent.

0.00

{0.01

W}

95.44 ECSxS/P/M/A004

47.72 ECSxS/P/M/A008

23.86 ECSxS/P/M/A016

11.93 ECSxS/P/M/A032

7.95 ECSxS/P/M/A048

5.96 ECSxS/P/M/A064

[C0085] Mot Ls

5.30

Leakage inductance of the motor

0.00

{0.01 mH}

200.00

[C0087] Mot speed

3700

Rated motor speed

300

{1 rpm}

16000

[C0088] Mot current

7.0

Rated motor current

0.5

{0.1 A}

500.0

[C0089] Mot

frequency

185

Rated motor frequency

10

{1 Hz}

1000

[C0090] Mot voltage

325

Rated motor voltage

50

{1 V}

500

[C0091] Mot cos phi

1.0

cos

j of the asynchronous motor

0.50

{0.01}

1.00

[C0095] Rotor pos adj

0

Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).

^ 151

0

Inactive

1

Active

C0110 Service Code

Fine adjustment − mutual
inductance

50

{1 %}

200

Advertising