Appendix – Lenze ECSCSxxx User Manual

Page 378

Advertising
background image

Appendix

Code table

13

l

378

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0178 Op timer

Running time meter
Read only

0

{1 sec}

4294967295 Time when the controller was

enabled

C0179 Mains timer

Power−on time meter
Only display

0

{1 sec}

4294967295 Time when the mains was

switched on

C0182 Ti S−shaped

20.00

Form of the S−curve for the

l

speed setpoint (for "speed
control")

l

torque setpoint (for "torque
control")

of the ramp function generator
(C0134 = 1)

^ 330

0.01

{0.01 s}

50.00 The higher the value, the bigger

the S−rounding.

C0183 Diagnostics

Drive diagnostics
Read only

l

Indicates fault or status
information

l

If several fault or status
information are to be shown
at the same time, the
information with the smallest
number is displayed

0

OK

No fault

101

Initialisation phase

102

TRIP/trouble

103

Emergency stop activated

104

IMP message

105

Power off

111

Operation inhibit C0135

112

Operation inhibit AIF

113

Operation inhibit CAN

121

Controller inhibit via X6/SI1

122

Internal controller inhibit 1

123

Internal controller inhibit 2

124

Controller inhibit via STOP key of the
keypad

125

Controller inhibit via AIF

126

Controller inhibit via CAN

131

Fail QSP

141

Restart protection

142

Pulse inhibit

High resistance power outputs

151

Quick stop (QSP) via terminal

152

Quick stop (QSP) via STOP key of the
keypad

153

Quick stop (QSP) via AIF

154

Quick stop (QSP) via CAN

160

PLC Stop

PLC must be started.

250

Warning