Appendix, Code table – Lenze ECSCSxxx User Manual

Page 368

Advertising
background image

Appendix

Code table

13

l

368

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0070 Vp speedCTRL

3.0

Proportional gain of speed
controller (V

pn

)

^ 154

0.00

{ 0.01}

127.99

C0071 Tn speedCTRL

24.0

Reset time − speed controller
(T

nn

)

^ 154

1.0

{0.5 ms}

6000.0

C0072 Td speedCTRL

0.0

Derivative gain of speed
controller (T

dn

)

^ 154

0.0

{0.1 ms}

32.0

C0074 Dynamics

0

Pilot control of the current
controller for higher dynamics

^ 149

0

Normal

1

Enhanced

C0075 Vp currCTRL

20.0

Proportional gain of current
controller (V

pi

)

The upper limit is
device−dependent.

^ 149

0.00

{0.01

W}

381.80 ECSxS/P/M/A004

190.90 ECSxS/P/M/A008

95.46 ECSxS/P/M/A016

47.72 ECSxS/P/M/A032

31.82 ECSxS/P/M/A048

23.86 ECSxS/P/M/A064

C0076 Tn currCTRL

5.0

Reset time of current controller
(T

ni

)

^ 149

0.01

{0.01 ms}

200.00

C0077 Vp fieldCTRL

5.0

Field controller gain (V

pF

)

^ 157

0.00

{0.01}

63.99

C0078 Tn fieldCTRL

20.0

Field controller reset time (T

nF

)

^ 157

1.0

{0.5 ms}

6000.0

C0079 DIS:Lh

Mutual inductance of the
asynchronous motor
Read only

0.0

{0.1 mH}

3276.7

[C0080] Res pole no.

1

Number of pole pairs of resolver

1

{1}

10

[C0081] Mot power

3.20

Rated motor power according to
nameplate

0.01

{0.01 kW}

500.00

[C0082] DIS:Rr

Rotor resistance of the
asynchronous motor
Read only

0.000

{0.001

W}

32.767

C0083 DIS:Tr

Rotor time constant of the
asynchronous motor
Read only

0.00

{0.01 ms}

327.67

Advertising