Monitoring functions

Configuring monitoring functions

Short circuit monitoring (OC1)

9

l

201

EDBCSXS064 EN 4.0

9.3.3

Short circuit monitoring (OC1)

Fault message

Monitoring function

System variable

Possible response

TRIP

Messag

e

Warnin

g

Off

011

OC1

Short circuit

MCTRL_bShortCircuit_b

·

· Default setting

üSetting possible

The monitoring process is activated if a short circuit occurs in the motor phases. This can
also be caused by an interturn fault in the machine.

ƒ

Monitoring can also be actuated at mains connection, if an earth fault occurs.

ƒ

If monitoring is actuated, the drive controller has to be disconnected from the
mains, and the short circuit has to be eliminated.

9.3.4

Earth fault monitoring (OC2)

Fault message

Monitoring function

System variable

Possible response

TRIP

Messag

e

Warnin

g

Off

012

OC2

Earth fault

MCTRL_bEarthFault_b

·

· Default setting

üSetting possible

The ECSxS... axis module is equipped with a standard earth fault detection.

ƒ

If monitoring is actuated, the drive controller has to be disconnected from the
mains, and the earth fault has to be eliminated.

Possible causes of an earth fault are:

ƒ

Short circuit to frame of the machine

ƒ

Short circuit of a phase to the shield

ƒ

Short circuit of a phase to PE