Appendix, Code table – Lenze ECSCSxxx User Manual

Page 365

Advertising
background image

Appendix

Code table

13

l

365

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0022 Imax current

à

I

max

limit

0

{0.01 A}

à

Device−dependent list

Max. current can be gathered
from the technical data.

C0023 Imax fld.weak

0

Maximum field weakening
current for synchronous
machines

0

{1 %}

100

C0026

Offset for relative analog signals
(AIN)

^ 266

^ 309

1 FCODE(offset)

0,0

−199,99

{0.01 %}

199,99 FCODE_nC26_1_a

2 FCODE(offset)

0,0

FCODE_nC26_2_a

C0027

Gain for relative analog signals
(AIN)

^ 266

^ 309

1 FCODE(gain)

100,0

−199,99

{0.01 %}

199,99 FCODE_nC27_1_a

2 FCODE(gain)

100,0

FCODE_nC27_2_a

C0030 DFOUT const

3

Constant for the digital
frequency signal DFOUT_nOut_v
on X8 in increments per
revolution

^ 304

^ 106

^ 113

0

256 incr./rev

1

512 incr./rev

2

1024 incr./rev

3

2048 incr./rev

4

4096 incr./rev

5

8192 incr./rev

6

16384 incr./rev

C0032 FCODE

Gearbox

1

Freely configurable code for
gearbox factor ?
(FCODE_nC32_a)

^ 309

−32767

{1}

32767

C0034 Mst current

0

Master voltage/master current
on analog input (AIN1_nIn_a)

^ 266

0

−10 ... + 10 V

Master voltage

1

+4 ... +20 mA

Master current

2

−20 ... +20 mA

C0037 Set−value rpm

0

Setpoint selection in rpm
(FCODE_nC37_a)

^ 309

−16000

{1 rpm}

16000

C0039

15 fixed setpoints
Can be retrieved via digital
signals SPEED−NSET.Jogx.

^ 326

1 JOG

SET−VALUE

0.00

−199.99

{0.01 %}

199.99 Relating to n

max

(C0011)

2 JOG

SET−VALUE

0.00

... JOG

SET−VALUE

0.00

14 JOG

SET−VALUE

0.00

15 JOG

SET−VALUE

0.00

Advertising
This manual is related to the following products: