8 ain1, Function library, Ain1 – Lenze ECSCSxxx User Manual

Page 266: Codes

Advertising
background image

Function library

AIn1

12

l

266

EDBCSXS064 EN 4.0

12.8

AIn1

Function

This function block provides the interface for analog input signals (differential signals) via
X6/AI−, AI+. The conditioned input signal is available at the function block output. When
using X6/AI−, AI+ as a master current input, cable−break monitoring is possible.

AI-

AI+

AG

X6

AIn1

C0034

C0026/1

C0027/1

920

920

C0400

AIn1-Out

AIn1-Error

ECSXA221

Fig. 12−8

AIn1 function block

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0026

Offset for relative analog signals
(AIN)

^ 266

^ 309

1 FCODE(offset)

0,0

−199,99

{0.01 %}

199,99 FCODE_nC26_1_a

2 FCODE(offset)

0,0

FCODE_nC26_2_a

C0027

Gain for relative analog signals
(AIN)

^ 266

^ 309

1 FCODE(gain)

100,0

−199,99

{0.01 %}

199,99 FCODE_nC27_1_a

2 FCODE(gain)

100,0

FCODE_nC27_2_a

C0034 Mst current

0

Master voltage/master current
on analog input (AIN1_nIn_a)

^ 266

0

−10 ... + 10 V

Master voltage

1

+4 ... +20 mA

Master current

2

−20 ... +20 mA

C0400 DIS: AnalogIn

Signal at the analog input
Read only

^ 266

−199.99

{0.01 %}

199.99

Advertising