20 digin (freely assignable digital inputs), Function library, Digin (freely assignable digital inputs) – Lenze ECSCSxxx User Manual

Page 307: Codes

Advertising
background image

Function library

DigIn (freely assignable digital inputs)

12

l

307

EDBCSXS064 EN 4.0

12.20

DigIn (freely assignable digital inputs)

Function

This function block reads and conditions the signals on X6/DI1 ... DI4.

ƒ

The configuration of the terminal polarity for the inputs X6/DI1 ... DI4 is effected via
C0114.

ƒ

The "safe torque off" safety function (

^ 71) is controlled via X6/SI1 and X6/SI2.

C0443

X6

DigIn

DI3

SI1

SI2

DI1

DI4

DI2

safe standstill

1

0

C0114/1...4

1

X6

C0443

132

133

134

135

131

136

mP

mP + Imp

DigIn-In1

DigIn-In2

DigIn-safe_standstill

DigIn-In4

DigIn-In3

DigIn-CInh

ECSXA241

Fig. 12−21

DigIn function block

Codes

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0114

Polarity of the digital inputs

^ 307

^ 121

1 DIGIN pol

0

HIGH level active

X6/DI1 (DIGIN_bIn1_b)

2 DIGIN pol

0

HIGH level active

X6/DI2 (DIGIN_bIn2_b)

3 DIGIN pol

0

HIGH level active

X6/DI3 (DIGIN_bIn3_b)

4 DIGIN pol

0

HIGH level active

X6/DI4 (DIGIN_bIn4_b)

0

HIGH level active

1

LOW level active

C0443 DIS: DIGIN

Signal status of the digital inputs
on X6 after consideration of the
polarity set under C0114.
Only display

^ 307

0

{1}

255

Bit 0

DIGIN1

X6/DI1

^ 121

Bit 1

DIGIN2

X6/DI2

Bit 2

DIGIN3

X6/DI3

Bit 3

DIGIN4

X6/DI4

Bit 4

DIGIN_safe_standstill

X6/SI2
0: Pulse inhibit is active
1: Pulse inhibit is inactive

^ 71

Bit 5

Free

Bit 6

DIGIN_CInh

X6/SI1
0: Controller is inhibited (CINH)
1: Controller is enabled

^ 71

Bit 7

Free

Advertising