2 setpoint processing, Function library – Lenze ECSCSxxx User Manual

Page 326

Advertising
background image

Function library

Speed (speed control)
Setpoint processing

12

l

326

EDBCSXS064 EN 4.0

12.27.2

Setpoint processing

12.27.2.1

Selecting the source for the speed setpoint

The function block "Speed" is supplied with the speed setpoint via the input
SPEED−NSET.NSet (C7431/1). The valid values are within the decimal range ±32767. The
speed setpoint is conditioned by a ramp function generator and special controllers.

In C0039/1 ... 15, 15 fixed setpoints (JOG) can be stored. The values can be stored
independent of the direction of rotation, since the direction of rotation can also be
changed with activated JOG values.

The fixed setpoints can be activated via the inputs SPEED−NSET.Jogx (C7411/3 ... /6). When
the fixed setpoints are active, the input SPEED−NSET.NSet is switched off.

Signal name

Source for the speed

setpoint

SPEED−Nset.Jog8

SPEED−NSET.Jog4

SPEED−Nset.Jog2

SPEED−Nset.Jog1

0

0

0

0

SPEED−NSET.NSet

0

0

0

1

C0039/1

0

0

1

0

C0039/2

0

0

1

1

C0039/3

0

1

0

0

C0039/4

0

1

0

1

C0039/5

0

1

1

0

C0039/6

0

1

1

1

C0039/7

1

0

0

0

C0039/8

1

0

0

1

C0039/9

1

0

1

0

C0039/10

1

0

1

1

C0039/11

1

1

0

0

C0039/12

1

1

0

1

C0039/13

1

1

1

0

C0039/14

1

1

1

1

C0039/15

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0039

15 fixed setpoints
Can be retrieved via digital
signals SPEED−NSET.Jogx.

^ 326

1 JOG

SET−VALUE

0.00

−199.99

{0.01 %}

199.99 Relating to n

max

(C0011)

2 JOG

SET−VALUE

0.00

... JOG

SET−VALUE

0.00

14 JOG

SET−VALUE

0.00

15 JOG

SET−VALUE

0.00

Advertising
This manual is related to the following products: