Code table

13

l

380

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0220 NSET Tir add

0.000

Acceleration time for the
additional setpoint

^ 331

0.000

{0.001 s}

999.999 Relating to speed variation

0 rpm ... n

max

(C0022)

C0221 NSET Tif add

0.000

Deceleration time for the
additional setpoint

^ 331

0.000

{0.001 s}

999.999 Relating to speed variation

0 rpm ... n

max

(C0011)

C0241 NSET RFG I = O

1.00

Threshold for message "Setpoint
reached"
On the ramp function generator
for

l

speed setpoint (for "speed
control")

l

torque setpoint (for "torque
control")

input signal = output signal.

^ 329

^ 352

0.00

{0.01 %}

100.00 100 % = n

max

C0244 BRK M set

0.00

Holding torque of the drive
against the motor holding brake

^ 340

^ 360

^ 102

−199.99

{0.01 %}

199.99 Referring to M

max

(C0057).

During the time set in C0196 the
drive generates the set torque
against the holding brake.

C0250 FCODE 1 Bit

0

Freely selectable digital signal
(1 bit)

^ 309

0

1

C0254 Vp angle CTRL

0.4000

Phase controller gain (V

p

)

^ 337

0.0000

{ 0.0001}

3.9999

C0300 Service Codes

Only the Lenze service is allowed
to make changes!

...

C0302

C0304 Service Codes

Only the Lenze service is allowed
to make changes!

...

C0310