Commissioning, Direction of rotation / quick stop (qsp), Holding brake – Lenze ECSCSxxx User Manual

Page 136: Analog input voltage supply, Switch for controller enable/inhibit, Motor system cable, Voltage supply of motor holding brake, Voltage supply of control, Controller enable, System cable feedback

Advertising
background image

Commissioning

Selecting the operating mode/control structure
Torque control with setpoint via analog input

6

l

136

EDBCSXS064 EN 4.0

L1

+UG

BR1

T1

DO1

B1

U

W

CH

CAH

CH

L2

-UG

+UG

+UG

BR0

T2

DI1

B2

V

PE

CL

CAL

CL

L3

-UG

+UG

DI1

DI2

CG

CAG

CG

PE

PE

-UG

PE

PE

DI2

DI3

PE

PE

DO1

DI4

CH

CH

+24

V

AI-

GND

CG

CG

D24

AI+

+24

V

CL

CL

GND

AG

SO

SI1

SI2

B+

B-

S24

PE

PE

X21

X23

X22

ECSxE...

ECSxA...

X6

X6

X25

X24

X7

X8

X4

X14

X4

K1

L1

L2

L3

N

PE

F4

F1

F2

F3

Z1

PES

PES

PES

PES

PES

PES

PES

PES

PES

PES

Off

On

K1

K1

K1

+

+

-

-

+

-

M

3~

R

J

6

2

0 2

1 3

4

7

5

6

9

+24 VDC

GND

:

;

<

F

1,6

A

ECSXA283

Fig. 6−14

Connection diagram for configuration 4000 (setpoint via analog input)

0

Direction of rotation / quick stop (QSP)

1

Direction of rotation / quick stop (QSP)

2

Fixed speed C0039/1

3

Holding brake

4

Analog input voltage supply

5

Switch for controller enable/inhibit

6

Motor system cable

7

Voltage supply of motor holding brake

9

Voltage supply of control

:

Controller enable

;

System cable feedback

<

DC−bus voltage
HF shield termination by large−surface PE connection
Twisted cables

)

Note!

In the wiring example (Fig. 6−14) a HIGH level is fixedly applied on X6/SI2
(pulses for power section enabled).

Advertising