4 mounting in cold-plate design, Mounting in cold−plate design, Mechanical installation – Lenze ECSCSxxx User Manual

Page 46

Advertising
background image

Mechanical installation

Mounting in cold−plate design

4

l

46

EDBCSXS064 EN 4.0

4.4

Mounting in cold−plate design

The axis modules ECSC... are intended for mounting in cold−plate design (e.g. on collective
coolers).

Requirements for collective coolers

The following requirements must be met to ensure a safe operation of the axis modules:

ƒ

Good thermal contact with the cooler
– The contact surface between collective cooler and axis module must be at least as

large as the cooling plate of the axis module.

– Smooth contact surface, max. deviation 0.05 mm.
– Connect the collective cooler with all specified screwed connections to the axis

module.

ƒ

Maintain the thermal resistance R

th

according to the table.

– The values apply for operating the axis modules under rated conditions.

Axis module

Power to be dissipated

Heat sink − environment

Type

Ploss [W]

R

th

[k/W]

ECSC

L004

14.0

0,31

ECSC

L008

29.0

ECSC

L016

64.0

ECSC

L032

117.0

0,13

ECSC

L048

132.0

ECSC

L064

158.0

0,11

L

Application software:

S = Speed & Torque

P = Posi & Shaft

M = Motion

A = Application

ƒ

Ambient conditions:
– Furthermore the rated data regarding the ambient temperature and the derating

factors at increased temperature apply to the axis modules (

^ 31 et seqq.).

– Temperature of the cooling plate ("Cold Plate"): max. +85 °C