Appendix, Code table – Lenze ECSCSxxx User Manual

Page 390

Advertising
background image

Appendix

Code table

13

l

390

EDBCSXS064 EN 4.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

10 User menu

0.00

Not assigned

11 User menu

11.00

C0011

Nmax

Input of the maximum speed

12 User menu

0.00

Not assigned

13 User menu

0.00

Not assigned

14 User menu

105.00

C0105

QSP Tif

Input of quick stop deceleration
time

15 User menu

0.00

Not assigned

16 User menu

70.00

C0070

Vp speed CTRL

Input of speed controller gain
(Vp)

17 User menu

71.00

C0071

Tn speed CTRL

Input of speed controller reset
time (Tn)

18 User menu

0.00

Not assigned

19 User menu

2100.00

C2100

Time slice

Input of time dial for cycl. task

20 User menu

2102.00

C2102

Task switch

Selection of the switching
function for cycl. task

21 User menu

2104.00

C2104

PLC autorun

Autom. start of the PLC program
after mains power−up

22 User menu

2106.00

C2106

Download protect

Write protection of the PLC
program

23 User menu

2108.00

C2108

PLC run/stop

Control of the PLC program

24 User menu

2111.00

C2111

GDC ID

Creation date of the PLC program

25 User menu

2113.00

C2113

PLC prog name

Name of the PLC program

26 User menu

2115.00

C2115

T−fct Credit

Number of technology units

27 User menu

0.00

Not assigned

28 User menu

0.00

Not assigned

29 User menu

0.00

Not assigned

30 User menu

0.00

Not assigned

31 User menu

94.00

C0094

Password

Parameter access protection for
the keypad

32 User menu

3.00

C0003

Par save

Save parameter set

[C0540] X8 Signal out

2

Function of the digital frequency
output signals on X8 (DFOUT)

^ 304

^ 103

0

DFOUT in [%]

1

DFOUT in [rpm]

2

Encoder simulation + zero pulse

®

DFOUT

C0545 PH offset

0

Phase offset

^ 304

0

{1 inc}

65535 1 revolution = 65535 increments

C0547 DIS: AN−IN

Analog signal on the input of the
DFOUT block
Read only

^ 304

−199.99

{0.00 %}

199.99

C0549 DIS: DF−IN

Speed on the input of the DFOUT
block
Only display

^ 304

−32767

{1 rpm}

32767

C0559 SD8 filter t

1

Filter time constant (SD8)

1

{1 ms}

200 Example:

If the setting is "10 ms", a
SD8−TRIP is actuated after 10 ms.

Advertising
This manual is related to the following products: