6 torque control with setpoint via motionbus (can), Torque control with setpoint via motionbus (can), Commissioning – Lenze ECSCSxxx User Manual

Page 139

Advertising
background image

Commissioning

Selecting the operating mode/control structure

Torque control with setpoint via MotionBus (CAN)

6

l

139

EDBCSXS064 EN 4.0

6.10.6

Torque control with setpoint via MotionBus (CAN)

Configuration C3005 = 4005

)

Note!

ƒ

Use the "input assistant for motor data" of the GDC for setting the motor
data (

^ 100).

ƒ

Reading the data via CAN1In requires an external Sync signal (from the
master control).

Set the following codes:

Code

Meaning

Further
information

DC−bus voltage thresholds and charge relay function

C0173 = x

DC−bus voltage thresholds

^ 99

C0175 = x

Charge relay function
(when using an ECS supply module: C0175 = 3)

^ 98

Maximum motor current

C0022 = x [A]

Maximum motor current (I

max

)

Controller configuration and feedback system

C3005 = 4005

Torque control with setpoint via MotionBus (CAN)

^ 126

C0495 = x

Feedback system

^ 103

Speed setpoint settings

C0011 = x [rpm]

Maximum speed

^ 355

C0012 = x [s]

Acceleration time

^ 351

C0013 = x [s]

Deceleration time

C0105 = x [s]

Quick stop deceleration time

^ 358

Speed limitation

C0472/4 = x [%]

Speed limit (positive value)

^ 349

C7131/1 = 52

FCODE C0472/4

C7531/2 = 651

InNeg−AnOut1

C7531/5 = 52

FCODE C0472/4

Application parameters

C0070 = x

Proportional gain (V

p

) of speed controller

^ 355

C0071 = x [ms]

Integral−action time (T

n

) of speed controller

Save parameters

C0003 = 1

Save all parameters

Advertising
This manual is related to the following products: