1 - 6

YASNAC PCNC Programming Manual

Chapter 1: Programming Basics

Note 1:

The unit of output increment (motion increment) and input increment of a linear axis is the
same as other linear axes (X-, Y-, and Z-axis). The linear axes indicated above can be treated
in exactly the same manner as other linear axes,

2:

When the inch system is selected by using inch/nm selection function, dimensions must be
input in units of inches as with other axes (X-, Y-, and Z-axis).

Fig. 1.1.1.2

Fifth Axis (b-axis) in the Right-hand Coordinate System

1.1.2

Least Input Increment and Least Output Increment

The least input and output increments vary depending on the type of controlled axis whether it is a
rotary axis or a linear axis.

(1) Least Input Increment

The least input increment to express axis movement distance that is input by using punched
tape or manual data input switches is indicated in Tables 1.9, 1.10, and 1.11.

Table 1.1.2.1:

Least Increment (Standard)

Table 1.1.2.2:

Least Increment (Sub Microns)

Linear Axis

*Rotary Axes

Metric Input

0.001 mm

0.001 deg.

Inch Input

0.0001 inch

0.001 deg.

Linear Axis

*Rotary Axes

Metric Input

0.0001 mm

0.001 deg.

Inch Input

0.00001 inch

0.001 deg.