4 - 113
YASNAC PCNC Programming Manual
Chapter 4: Enhanced Level Commands
time. Therefore, it is not valid for the number of use or the number of holes.
Example of Programming
G125 P1.5;
With the commands indicated above, the life count data (distance, time) are counted in
1.5 times the normal counting mode.
Distance:
2 m
‡ 3 counts
Time:
2 minutes
‡ 3 counts