4 - 113

YASNAC PCNC Programming Manual

Chapter 4: Enhanced Level Commands

time. Therefore, it is not valid for the number of use or the number of holes.

Example of Programming

G125 P1.5;

With the commands indicated above, the life count data (distance, time) are counted in
1.5 times the normal counting mode.

Distance:

2 m

‡ 3 counts

Time:

2 minutes

‡ 3 counts