4 - 147

YASNAC PCNC Programming Manual

Chapter 4: Enhanced Level Commands

the state in which the complete signal is checked. In the state that the miscellaneous
function complete signal is not checked, the program advances to the next block with-
out waiting for the input of the complete signal even when the buffering stop M code
(M00, M01, M02, M30) is specified.

When the NC is reset, the setting for #3003 is “0”.

Table 4.4.3.14

Control for Single-Block Stop and Miscellaneous Function
Completion Waiting

Example of Programming

(j) Setting for feed hold, feedrate override, and positioning completion control

For the control of feed hold, feedrate override, and positioning completion, system vari-
able #3004 is provided and by setting an appropriate value for this system variable, it is
possible to make these functions valid or invalid.

When the NC is reset, the setting is reset to “#3004 = 0”

#3003

SINGLE-BLOCK Switch

Miscellaneous Function Complete Signal (FIN)

0

Valid

Checked

1

Invalid

Checked

2

Valid

Not checked

3

Invalid

Not checked