Yaskawa YASNAC PC NC Programming Manual User Manual
Page 284

4 - 147
YASNAC PCNC Programming Manual
Chapter 4: Enhanced Level Commands
the state in which the complete signal is checked. In the state that the miscellaneous
function complete signal is not checked, the program advances to the next block with-
out waiting for the input of the complete signal even when the buffering stop M code
(M00, M01, M02, M30) is specified.
When the NC is reset, the setting for #3003 is “0”.
Table 4.4.3.14
Control for Single-Block Stop and Miscellaneous Function
Completion Waiting
Example of Programming
(j) Setting for feed hold, feedrate override, and positioning completion control
For the control of feed hold, feedrate override, and positioning completion, system vari-
able #3004 is provided and by setting an appropriate value for this system variable, it is
possible to make these functions valid or invalid.
When the NC is reset, the setting is reset to “#3004 = 0”
#3003
SINGLE-BLOCK Switch
Miscellaneous Function Complete Signal (FIN)
0
Valid
Checked
1
Invalid
Checked
2
Valid
Not checked
3
Invalid
Not checked