Table 4.1.3.1 list of alarm, Table 4.1.3.2 list of parameter – Yaskawa YASNAC PC NC Programming Manual User Manual

Page 180

Advertising
background image

4 - 43

YASNAC PCNC Programming Manual

Chapter 4: Enhanced Level Commands

(d) Alarm code

Table 4.1.3.1

List of Alarm

(7) Parameters and input/Output Signals Related to Solid Tap Function

(a) List of parameters

Table 4.1.3.2

List of Parameter

Alarm Code

Description

Causes

0250

A command not
allowed in the
solid tap mode

• In the G93 block, a command other than G93, S, F, and N is

specified.

• G93 is specified in other than the G00 or G011 mode estab-

lished by the 01-group G code.

• A G code not allowed in the G93 mode is specified.

• Pitch F specified for solid tap operation is greater than the

allowable maximum value (200 mm/rev).

2191

Solid tap input/
output error

• When solid tap operation is executed, the position control loop

is not established for the spindle.

• When spindle indexing is executed, SLPC is turned OFF be-

for the completion of indexing.

Item

Parameter

Setting and Setting

Range

Spindle speed for checking-
Spindle stop after indexing

pm1225: 1st spindle gear A
pm l 226: 1st spindle gear B

Setting

11 r/

min
Range

1 -

255

Error detect ON area with
spindle position loop estab-
lished

pm1331: 1st spindle gear A
pm1332: 1st spindle gear B

Setting

1 = 1

least detect-

able

increment
Range

1 -

255

Servo error area with spindle
position loop ON

pm1351: 1st spindle gear A
pm1352: 1st spindle gear B

Range

l = l%

Setting

0 -

200

Spindle speed for command
voltage of 10 V with the gear
used for solid tap

pm 1415: 1st spindle gear A
pm 1435: 1st spindle gear B

Range

1 = 1

r/min
Setting

1 -

32767

Advertising