Table 1.2.3.3: parameters pm2865 and pm2866 – Yaskawa YASNAC PC NC Programming Manual User Manual

Page 24

Advertising
background image

1 - 17

YASNAC PCNC Programming Manual

Chapter 1: Programming Basics

When using the F1-digit feed function, it is possible to optimize the selected feedrate by turning
the manual pulse generator while the F1-DIGIT switch is ON. Increase or decrease of increments
per pulse (F1-digit multiply) should be set for the parameters indicated in Table 1.2.3.2.

Table 1.2.3.2:

Parameter Numbers Used for Setting F1-digit Multiply for the para

Note: Value “1”= 0.1 mm/min per pulse

If increase/decrease increments per pulse is set for these parameters, the value set for the parame-
ters in Table 1.31 is updated in response to the manual pulse generator operation.

Parameters indicated in Table 1.33 are used to set the upper limits of the feedrate for F1-digit fee-
drate selection. If a value larger than the allowable maximum feedrate set for parameter pm2800
is set, it is disregarded and replaced with the value set for pm2800.

Table 1.2.3.3:

Parameters pm2865 and pm2866

1. When the 1-digit numerals are set to the parameters pm0802 to pm0828, and pm2004 D0

= 0, feedrate on the screen is displayed as “0”. However, the machine moves in units of
0.1 to 0.9mm/min or 0.01 to 0.09 inch/min.

2. If “F0”is specified, alarm “0370” occurs.

F Command

Parameter Numbers

F1

pm2111

F2

pm2112

F3

pm2113

F4

pm2114

F5

pm2115

F6

pm2116

F7

pm2117

F8

pm2118

F9

pm2119

Parameter Numbers

Description

pm2865

Allowable maximum feedrate for F1 to F4

pm2866

Allowable maximum feedrate for F5 to F9

pm2004 D0 = 0

Feedrate at the deceleration of 0.001mm or 0.0001 inch is F6.0
mm/min or F4.1 inch/min.

pm2004 D0 = 1

Feedrate at the deceleration of 0.001mm or 0.0001 inch is F6.1
mm/min or F4.2 inch/min.