Figure 4.1.1.8 commands of back boring cycle (g77) – Yaskawa YASNAC PC NC Programming Manual User Manual

Page 163

Advertising
background image

4 - 26

YASNAC PCNC Programming Manual

Chapter 4: Enhanced Level Commands

(b) Back boring command (G77)

If addresses I or J are specified with address Q in the same block, addresses I and J are
disregarded.

For the dwell at the bottom of a hole, the setting for pm0400 is given priority to the
commands specified in a program.

Parameter pm0400 is valid if “pm4017 D3 = 1”.

Axis shift feedrate is set for parameter pm2864. If “pm2864 = 0”, feedrate specified
by an F command is used.

Since address Q is modal, if a Q command is specified before I or J commands, these
commands are disregarded. To make I and J commands valid, specify them after can-
celing a canned cycle by G80.

Programming for fixed shift distance

G77_X_ Y_ Z_ R_ Q_ L_ F_ P *_ W *_;

Programming for variable shift distance;

G77_X_ Y_ Z_ R_ I_ J_ L_F_ P *_ W *_;

FIGURE 4.1.1.8 Commands of Back Boring Cycle (G77)