4 - 130

YASNAC PCNC Programming Manual

Chapter 4: Enhanced Level Commands

Table 4.4.3.2

Option Type and Expanded Common Variables

(3) System Variables

With the system variables, their use is predetermined as indicated in Table 4.4.3.3.

Table 4.4.3.3

System Variables

Option Type

Number of Sets

a

#100 to #149 (50 sets)
#500 to #559 (60 sets)

b

#100 to #199 (100 sets)
#500 to #599 (100 sets)

c

#100 to #199 (100 sets)
#500 to #699 (200 sets)

d

#100 to #299 (200 sets)
#500 to #999 (500 sets)

Type of System Variable

System Variable Number

Interface input signals

#1000 to #1031, #1032

Interface output signals

#1100 to #1131, #1132

Tool offset amount work coordinate system shift distance

#2001 to #2299
#12001 to #13199

Alarm message display

#3000

Clock #3001,

#3002

Control for single-block stop, and miscellaneous function
complete wait

#3003

Control for feed hold, feedrate override, and exact stop

#3004

RS-232C data output

#3100

Modal information

#4000 to #4999

Position information

#5000 to #5999