Table 1.1.2.3:

Least Increment (Sub Sub-microns)

Note: Selection of “mm-input” and “inch-input” is made by the setting parameter pm0007 D0.

(2) Least Output Increment

The least output increment indicates the “minimum unit” of axis movement that is determined
by the mechanical system. By selecting the option, it is possible to select the output unit sys-
tem between “mm” and “inches”.

Table 1.1.2.4:

Least Output Unit (Standard)

Table 1.1.2.5:

Least Increment (Sub Microns)

Table 1.1.2.6:

Least Increment (Sub Sub-microns)

Linear Axis

*Rotary Axes

Metric Input

0.00001 mm

0.001 deg.

Inch Input

0.000001 inch

0.001 deg.

Linear Axis

*Rotary Axes

Metric Output

0.001 mm

0.001 deg.

Inch Output

0.0001 inch

0.001 deg.

Linear Axis

*Rotary Axes

Metric Output

0.0001 mm

0.001 deg.

Inch Output

0.00001 inch

0.001 deg.

Linear Axis

*Rotary Axes

Metric Output

0.00001 mm

0.001 deg.

Inch Output

0.000001 inch

0.001 deg.