Yaskawa YASNAC PC NC Programming Manual User Manual
Page 298
Advertising
4 - 161
YASNAC PCNC Programming Manual
Chapter 4: Enhanced Level Commands
•
The <number> in “DO number” and “END <number> must be the same number, and
DO and END must be specified as a pair.
Note: °: Correct, ×: Incorrect
•
The same <number> can be used as many times as required. However, the range of
repetition must not overlap.
Note:
°: Correct, ×: Incorrect
•
Nesting of DO to END loop is allowed for up to three levels in a microprogram or sub-
program. From the DO to END loop, it is possible to call up a microprogram or sub-
program. In the call up program, nesting of the DO to END loop is also allowed for up
to three levels.
Note:
0: Correct