5 machine coordinate system (g53), Figure 3.1.5.1: machine coordinate system – Yaskawa YASNAC PC NC Programming Manual User Manual

Page 63

Advertising
background image

3 - 13

YASNAC PCNC Programming Manual

Chapter 3: Movement Control Commands

(2) Supplements to Local Coordinate System Setting Commands

•

In the state where a workpiece coordinate system and local coordinate system have
been set, G92 command must not be executed. An operation to set a coordinate sys-
tem at the NC operation panel must also be avoided. Also refer to supplements indi-
cated in “Base Coordinate System (G92)”.

•

If G52 is executed while this optional function is not selected, it cancels the workpiece
coordinate system (G54 to G59).

•

The local coordinate system is canceled by the reset operation.

3.1.5

Machine Coordinate System (G53)

The machine coordinate system, specific to the machine, is determined by the execution of refer-
ence point return operation. It has the origin (0, 0, 0) at the reference point.

(1) Command Format

By specifying “(G90) G53 X • • • Y • • • Z • • •;”, axis move commands in this are executed in
the machine coordinate system. G53 is a non-modal G code.

FIGURE 3.1.5.1: Machine Coordinate System