5 machine coordinate system (g53), Figure 3.1.5.1: machine coordinate system – Yaskawa YASNAC PC NC Programming Manual User Manual

Page 63

Advertising
background image

3 - 13

YASNAC PCNC Programming Manual

Chapter 3: Movement Control Commands

(2) Supplements to Local Coordinate System Setting Commands

In the state where a workpiece coordinate system and local coordinate system have
been set, G92 command must not be executed. An operation to set a coordinate sys-
tem at the NC operation panel must also be avoided. Also refer to supplements indi-
cated in “Base Coordinate System (G92)”.

If G52 is executed while this optional function is not selected, it cancels the workpiece
coordinate system (G54 to G59).

The local coordinate system is canceled by the reset operation.

3.1.5

Machine Coordinate System (G53)

The machine coordinate system, specific to the machine, is determined by the execution of refer-
ence point return operation. It has the origin (0, 0, 0) at the reference point.

(1) Command Format

By specifying “(G90) G53 X • • • Y • • • Z • • •;”, axis move commands in this are executed in
the machine coordinate system. G53 is a non-modal G code.

FIGURE 3.1.5.1: Machine Coordinate System