l

If both constraints are selected, each constraint accounts for 50% of the
edge score.

Magnitude Constraint

The Magnitude constraint is based on edge values relative to the Magnitude
Threshold, which is represented in the display by two red lines.

Edges having a magnitude equal to or exceeding the Magnitude Threshold
receive a score of 1. Edges with values below the Magnitude Threshold receive a
score ranging from 0 to 0.999, according to a manually set magnitude con-
straint function.

The Magnitude Threshold value can be modified in the Advanced Parameters
section of the tool interface.

A Magnitude Constraint must be defined individually for each edge of an edge
pair configuration.

The following figure shows examples of two different setups for a magnitude
constraint function.

To set a Magnitude Constraint:

1. In the drop-down list above the Function Editor, select First Edge Mag-

nitude Constraint or Second Edge Magnitude Constraint.
If either edge does not have the Magnitude box checked, it will not be
shown in the drop-down list.

2. In the Function Editor, use the mouse to drag handles and set the mag-

nitude limits. See examples in the following figure.

Setting the Magnitude Constraint in the Function Editor

Position Constraint

Position constraints restrict the caliper’s search for edges to a specific zone of

Configuring Arc Caliper Properties

AdeptSight User's Guide, Version 3.2.x, Updated: 8/23/2012