Object

Definition

Elapsed Time

The Elapsed Time is the total execution time of
the Arc Edge Locator. Elapsed Time is not visible in
the results grid, but it is displayed at the bottom
left of the Display window after each iteration of
the Arc Edge Locator.

Instance

The identification number of the edge. Enabling
Edge Sort affects the order of edge numbering.

Frame/Group

The frame or group to which the result belongs.

Edge X

The X coordinate of the center point for each edge
segment.

Edge Y

The Y coordinate of the center point for each edge
segment.

Edge Score

Score is the calculated score, between 0 and 1, for
each edge. The score is calculated according to the
defined constraint functions. If both Position and
Magnitude constraints are enabled, each con-
straint accounts for 50% of the score.

Radius

Radius of the edge.

Position Score

Score, between 0 and 1, for the edge, calculated
according to the Position Constraint function.

Magnitude

Magnitude indicates how well the region of inter-
est arc matches the found arc.
This will be negative if the found arc is a reflection
of the region of interest arc.

The Magnitude of the edge indicates its peak value
in the magnitude curve.

Magnitude Score

Score, between 0 and 1, for the edge, calculated
according to the Magnitude Constraint function.