Configuring caliper properties - advanced, Edge detection parameters, Tool sampling parameters – Adept AdeptSight User Guide User Manual

Page 357

Advertising
background image

Configuring Caliper Properties - Advanced

The Advanced Properties section of the Caliper tool interface provides access to advanced Cal-
iper parameters and properties.

Edge Detection Parameters

Edge Detection settings configure the parameters that the Caliper will use to find potential
edges in the region of interest. The display represents the Caliper region of interest and pro-
vides information to assist in configuring Edge Detection parameters.

Edge Filter Half-Width

The filtering process attenuates peaks in the magnitude curve that are caused by noise. Edge
Filter Half Width should be set to a value approximately equivalent to the width of the edge,
in pixels. An incorrect value can cause edges to be incorrectly detected.

Tool Sampling Parameters

Sampling refers to the procedure used by the tool for gathering values within the portion of
the input image that is bounded by the tool region of interest. Two sampling parameters, the
Sampling Step and Bilinear Interpolation, can be used to create the desired balance between
speed and accuracy.

Bilinear Interpolation

Bilinear Interpolation uses pixel averaging to improve the quality of the image. It is applied
before the image is analyzed.

To ensure subpixel accuracy in inspection applications, Bilinear Interpolation should always
be set to True (enabled). Non-interpolated sampling (Bilinear Interpolation disabled) should
only be used in applications where the speed requirements are more critical than accuracy.

Custom Sampling Step (1 - 100)

The Sampling Step is the step used by the tool to sample the area of the input image that is
bounded by the tool region of interest. The sampling step represents the height and the
width of a sampled pixel.

For applications where a more specific tradeoff between speed and accuracy must be estab-
lished, the sampling step can be modified by enabling the Custom Sampling Step and setting
the desired value.

Configuring Caliper Properties - Advanced

AdeptSight User's Guide, Version 3.2.x, Updated: 8/23/2012

Page 357