Intel® PXA26x Processor Family Developer’s Manual

3-39

Clocks and Power Manager

3.6.3

Oscillator Configuration Register (OSCC)

The OSCC, refer to

Table 3-23

, controls the 32.768-KHz oscillator configuration. It contains two

bits, the set-only 32.768-KHz OON and the read-only 32.768-KHz OOK. The OON bit enables the
external 32.768-KHz oscillator and can only be set by software. When the oscillator is enabled, it
takes up to 10 seconds to stabilize. When the oscillator is stabilized, the processor sets the OOK bit.

When the OOK bit is set, the RTC and power manager are clocked from the 32.768-KHz oscillator.
Otherwise, the 3.6864-MHz oscillator is used. The OPDE bit, which allows the 3.6864-MHz
oscillator to be disabled in sleep mode, is ignored (treated as if it were clear) if the OOK bit is clear.
OOK can only be reset by hardware reset.

This is a read/write register. Ignore reads from reserved bits. Write zeros to reserved bits.

3.6.4

Clocks Manager Register Locations

Table 3-24

shows the registers associated with the clocks manager and the physical addresses used

to access them.

Table 3-23. OSCC Bit Definitions

0x4130_0008

OSCC

Clocks and Power Manager

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

Reserved

OO

N

OO

K

Reset

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

[31:2]

Reserved

1

OON

32.768-KHz OON (write-once only bit):

0 – 32.768-KHz oscillator is disabled. The 3.6864-MHz oscillator (divided by 112) clocks

the real time clock and power manager.

1 – 32.768-KHz oscillator is enabled. OON can not be cleared once written except by

hardware reset.

Cleared by hardware reset.

0

OOK

32.768-KHz OOK (read-only bit):

0 – 32.768-KHz oscillator is disabled or not stable. The 3.6864-MHz oscillator (divided by

112) clocks the real time clock and power manager.

1 – 32.768-KHz oscillator has been enabled (OON=1) and stabilized. It will clock the real

time clock and power manager.

Cleared by hardware reset.

Table 3-24. Clocks Manager Register Locations

Address

Name

Description

0x4130 0000

CCCR

Core Clock Configuration Register

0x4130 0004

CKEN

Clock Enable Register

0x4130 0008

OSCC

Oscillator Configuration Register