Intel PXA26X User Manual

Page 365

Advertising
background image

Intel® PXA26x Processor Family Developer’s Manual

9-27

Inter-Integrated Circuit Bus Interface Unit

Table 9-12. I

2

C Status Register - ISR (Sheet 1 of 2)

Physical Address

4030_1698

I

2

C Status Register

I

2

C

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

R

eser

ved

BE

D

SA

D

GC

AD

IR

F

ITE

AL

D

SS

D

IB

B

UB

AC

KN

A

K

RW

M

Reset

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

31:11

Reserved

10

BED

BUS ERROR DETECTED:

0 – No error detected.

1 – The I

2

C unit sets this bit when it detects one of the following error conditions:

As a master transmitter, no ACK is detected on the interface after a byte is sent.

As a slave receiver, the I

2

C unit generates a NAK pulse.

NOTE: When an error occurs, I

2

C bus transactions continue. Software must ensure that

misplaced START and STOP conditions do not occur. See

Section 9.4.4,

“Arbitration”

.

To clear this bit, write a 1 to it.

9

SAD

SLAVE ADDRESS DETECTED:

0 – No slave address detected.

1 – I

2

C unit detected a 7-bit address that matches the general call address or ISAR. An

interrupt is signalled when the SADIE interrupt is set to a 1.

To clear this bit, write a 1 to it.

8

GCAD

GENERAL CALL ADDRESS DETECTED:

0 – No general call address received.

1 – I

2

C unit received a general call address.

7

IRF

IDBR RECEIVE FULL:

0 – The IDBR has not received a new data byte or the I

2

C unit is idle.

1 – The IDBR register received a new data byte from the I

2

C bus. An interrupt is signalled

when the IRFIE is set to a 1.

To clear this bit, write a 1 to it.

6

ITE

IDBR TRANSMIT EMPTY:

0 – The data byte is still being transmitted.

1 – The I

2

C unit has finished transmitting a data byte on the I

2

C bus. An interrupt is

signalled when the ITEIE interrupt is set to 1.

To clear this bit, write a 1 to it.

5

ALD

ARBITRATION LOSS DETECTED:

Used during multi-master operation.

0 – Cleared when arbitration is won or never took place.

1 – Set when the I

2

C unit loses arbitration.

To clear this bit, write a 1 to it.

4

SSD

SLAVE STOP DETECTED:

0 – No STOP detected.

1 – Set when the I

2

C unit detects a STOP while in slave-receive or slave-transmit mode.

To clear this bit, write a 1 to it.

3

IBB

I

2

C BUS BUSY:

0 – I

2

C bus is idle or the I

2

C unit is using the bus (i.e., unit busy).

1 – Set when the I

2

C bus is busy but the I

2

C unit is not involved in the transaction.