Planet Technology IP DSLAM IDL-4801 User Manual

Page 289

Advertising
background image

IP DSLAM

289

Type: Modify -- Optional

Valid values: 0 - 310

atucconfpml2minrate

<atucconfpml2minrate-val>

PM configuration parameter, related to the L2 low power state. This

parameter specifies the minimum net data rate during the low power

state (L2). The data rate is coded in bit/s, and can range from 0x1F40

(8000) bps to 0xFA000 (1024000) bps.

Type: Modify -- Optional

Valid values: 0x1F40 - 0xFA000

atucconfmsgminds

<atucconfmsgminds-val>

Configures downstream overhead channel bandwidth. This feature is

not supported by DSLPHY as yet.

Type: Modify -- Optional

Valid values: 4000 - 64000

aturconfmsgminus

<aturconfmsgminus-val>

Configures upstream overhead channel bandwidth.This feature is not

supported by DSLPHY as yet.

Type: Modify -- Optional

Valid values: 4000 - 64000

atucminsnrmgn

<atucminsnrmgn-val>

Atuc Configured Minimum Signal/Noise Margin. This is the Noise

Margin, the modem must achieve with a BER of 10 to the power -7 or

better, to successfully complete initialization. The default value

mentioned is an indicative value only.

Type: Modify -- Optional

Valid values: 0 - 310

aturminsnrmgn

<aturminsnrmgn-val>

Atuc Configured Minimum Signal/Noise Margin. This is the Noise

Margin, the modem must achieve with a BER of 10 to the power -7 or

better, to successfully complete initialization. The default value

mentioned is an indicative value only.

Type: Modify -- Optional

Valid values: 0 - 310

atucfrontenddesigntype

El1508 | El1528 | Le87213

Front end hardware reference design

Type: Modify -- Optional

atuchwpwrreduction Disable

| Enable

Hardware configuration parameter

Type: Modify -- Optional

atucgsusbitswap Disable |

Enable

This parameter enables/disables upstream bit swapping

Type: Modify -- Optional

aturmaxsnrmgn

<aturmaxsnrmgn-val>

Configured Maximum acceptable downstream Signal/Noise Margin. If

the Noise Margin is above this the modem attempts to reduce its power

output to optimize its operation. The value set by the user is in dB/10,

and ranges from 0 to 31 dB in 1 dB steps.

Type: Modify -- Optional

Valid values: 0 - 310