314

Carrier Sense Errors : 18 Too Long Frames : 19

Mac Rx Error Frames : 20 Duplex Status :

FullDuplex

Output field:

Field

Description

IfName

An index name that uniquely identifies an interface to an

ethernet-like medium.

Alignment Errors

A count of frames received on a particular interface that are not

an integral number of octets in length and do not pass the FCS

check. The count represented by an instance of this object is

incremented when the alignmentError status is returned by the

MAC service to the LLC (or other MAC user). Received frames

for which multiple error conditions pertain are, according to the

conventions of IEEE 802.3 Layer Management, counted

exclusively according to the error status presented to the LLC.

This counter does not increment for group encoding schemes

greater than 4 bits per group. For interfaces operating at 10 Gb/s,

this counter can roll over in less than 5 minutes if it is

incrementing at its maximum rate. Since that amount of time

could be less than a management station's poll cycle time, in

order to avoid a loss of information, a management station is

advised to poll the dot3HCStatsAlignmentErrors object for 10

Gb/s or faster interfaces. Discontinuities in the value of this

counter can occur at re-initialization of the management system,

and at other times as indicated by the value of

ifCounterDiscontinuityTime.

FCS Errors

A count of frames received on a particular interface that are an

integral number of octets in length but do not pass the FCS

check. This count does not include frames received with

frame-too-long or frame-too-short error. The count represented

by an instance of this object is incremented when the

frameCheckError status is returned by the MAC service to the

LLC (or other MAC user). Received frames for which multiple

error conditions pertain are, according to the conventions of IEEE

802.3 Layer Management, counted exclusively according to the

error status presented to the LLC. For interfaces operating at 10

Gb/s, this counter can roll over in less than 5 minutes if it is

incrementing at its maximum rate. Since that amount of time

could be less than a management station's poll cycle time, in