Planet Technology IP DSLAM IDL-4801 User Manual

Page 316

Advertising
background image

IDL series User Guide

316

re-initialization of the management system, and at other times as

indicated by the value of ifCounterDiscontinuityTime.

Excess Collisions

Frames

A count of frames for which transmission on a particular interface

fails due to excessive collisions. This counter does not increment

when the interface is operating in full-duplex mode.

Discontinuities in the value of this counter can occur at

re-initialization of the management system, and at other times as

indicated by the value of ifCounterDiscontinuityTime.

Mac Tx Errors Frames

A count of frames for which transmission on a particular interface

fails due to an internal MAC sublayer transmit error. A frame is

only counted by an instance of this object if it is not counted by

the corresponding instance of either the dot3StatsLateCollisions

object, the dot3StatsExcessiveCollisions object, or the

dot3StatsCarrierSenseErrors object. The precise meaning of the

count represented by an instance of this object is

implementation-specific. In particular, an instance of this object

may represent a count of transmission errors on a particular

interface that are not otherwise counted. For interfaces operating

at 10 Gb/s, this counter can roll over in less than 5 minutes if it is

incrementing at its maximum rate. Since that amount of time

could be less than a management station's poll cycle time, in

order to avoid a loss of information, a management station is

advised to poll the dot3HCStatsInternalMacTransmitErrors object

for 10 Gb/s or faster interfaces. Discontinuities in the value of this

counter can occur at re-initialization of the management system,

and at other times as indicated by the value of

ifCounterDiscontinuityTime.

Carrier Sense Errors

The number of times that the carrier sense condition was lost or

never asserted when attempting to transmit a frame on a

particular interface. The count represented by an instance of this

object is incremented at most once per transmission attempt,

even if the carrier sense condition fluctuates during a

transmission attempt. This counter does not increment when the

interface is operating in full-duplex mode. Discontinuities in the

value of this counter can occur at re-initialization of the

management system, and at other times as indicated by the value

of ifCounterDiscontinuityTime.

Too Long Frames

A count of frames received on a particular interface that exceed

the maximum permitted frame size. The count represented by an

instance of this object is incremented when the frameTooLong

status is returned by the MAC service to the LLC (or other MAC

Advertising