610

Valid values: 1-4

Systime <system-time>

This specifies the current system time.

Type: Optional

Valid values: System Time String in format. The total string

length must be 20 characters. Single digits should be

prepended with a `0', e.g. `1' should be given as `01' mon dd

hh:mm:ss year e.g. "Feb 01 21:20:10 2001"

dst <on | off>

This specifies if the Daylight Savings Time has been

enabled or not.

Type: Optional

Valid values: on|off

timezone <timezone>

Time zone

Type: Optional

Valid values: Given below, are the valid values withinì ì,

followed by their descriptions.

"IDLW" - International Date Line West

"NT" - Nome

"HST" - Hawaii Standard

ìCAT" - Central Alaska

"AHST"- Alaska-Hawaii Standard

"YST" - Yukon Standard

"PST"- US Pacific Standard

"MST"- US Mountain Standard

"CST"- US Central Standard

"EST"- US Eastern Standard

"AST"- Atlantic Standard

"NFST"- Newfoundland Standard

"NFT"- Newfoundland

"BRST"-Brazil Standard

"AT"- Azores

ìWAT" - West Africa

"GMT" - Greenwich Mean

"UTC" - Universal (Coordinated)

"WET" - Western European

"CET" - Central European

"FWT" - French Winter

"MET" - Middle European

"MEWT" - Middle European Winter

"SWT" - Swedish Winter

"EET" - Eastern Europe, Russia Zone 1