Connect the inverters to each other

Connect using a network cable (patch cable)

Where to connect: 2 RJ45 sockets

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. Insert the RJ45 plug into any RJ45 socket on the first inverter.

3. Insert the other end of the wire into any RJ45 socket on inverter 2.

4. Connect the other inverters to each other in the same way.

5. Terminate in the last inverter in accordance with the manufacturer's specifications.

6. Close the inverter if no other inverters are to be connected.

7. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Central inverter
Overview

Integrated interface

Connected using network cable (patch cable) and Ethernet router or switch

Communication address must be allocated.

Installation steps

Allocate communication address

Connect inverters to the Solar-Log™

Connect the inverters to each other

Caution

The IP addresses for the inverter must be in the same Class C network as the Solar-Log™.
Alternatively, it is sufficient if the first three groups of digits in the IP addresses are the
same.

Allocate communication address

Setting: Using the inverter operating display.
Please follow the instructions in the manufacturer's manual.

Connect inverters and the Solar-Log™�

The wiring is done using a

network cable (patch cable) and the

Ethernet router or switch.

Procedure

1.

Set different unit IPs on each inverter in accordance with the inverter's instructions.

2. Connect the Solar-Log™ and the inverter to the router or switch.