8 aros solar technology – Solare Datensysteme Solar-Log User Manual

Page 42

Advertising
background image

42

AROS Solar Technology

AROS Solar Technology (RS422)

8 AROS Solar Technology

8�1

AROS Solar Technology (RS422)

Easy Installation

Termination

Addressing

Interface

No

Yes

No

RS422

Select "Aros 422" during the inverter detection

Overview

Integrated interface

Where to connect: Terminal strip inside the inverter

4-pin cable only on RS485/422 B/C connection of the Solar-Log™

Communication address does not have to be assigned

Note:

The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup in the

Configuration | Device | Configuration | Order

menu box.

The inverters can be identified using the displayed serial number.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Connect inverters to the Solar-Log™

The wiring is done using a

self-made cable connection with terminal block connector.