Solare Datensysteme Solar-Log User Manual

Page 99

Advertising
background image

99

Europa-Solar AG

Europa-Solar AG

Solar-Log™ terminal strip connector

RJ45 inverter

Terminal

PIN

► 1

► Pin 3

► 4

► Pin 6

► 5

► Pin 1

► 6

► Pin 2

3. Insert the RJ45 plug into any RJ45 socket on inverter 1.

4. If only one inverter is to be connected terminate this in accordance with the inverter instructions.

5. Close the inverter if no other inverters are to be connected.

6. Insert the terminal block connector into the Solar-Log™ RS485/422 B socket.

Connect the inverters to each other

Connect using a network cable (patch cable)

Where to connect: RJ45 socket inside the inverter

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. Insert the RJ45 plug into any RJ45 socket on inverter 1.

3. Insert the other end of the wire into any RJ45 socket on inverter 2.

4. Connect the other inverters to each other in the same way.

5. Terminate in the last inverter according to the inverter instructions.

6. Close inverters.

Advertising