89 sunways, 89�1 sunways - at/nt/pt – Solare Datensysteme Solar-Log User Manual

Page 275

Advertising
background image

275

Sunways

Sunways - AT/NT/PT

89 Sunways

89�1 Sunways - AT/NT/PT

Easy Installation

Termination

Addressing

Interface

Yes

Yes

Yes

RS485

Overview

Integrated interface

Where to connect: Terminal strip inside the inverter

-

750 V models:

4 RS485 terminals on 10 pin terminal strip

-

850 V models:

4 pin RS485 terminal strip

2-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made Sunways data cable (optional extra; not supplied)

or

self-made, shielded 2 wire data cable and terminal block connector.

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. Pull the free wires through the wire opening in the inverter.

3. If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

Terminal

► 1

► RS485+

► 4

► RS485-

4. If only one inverter is to be connected, terminate it according to the inverter instructions.

5. Close the inverter if no other inverters are to be connected.

6. Insert the terminal block connector into the Solar-Log™ RS485 socket.