Effekta

Effekta

23 Effekta

23�1 Effekta

Easy Installation

Termination

Addressing

Interface

No

Jumper

Yes

RS485

Select "Effekta ES" during the inverter detection

Overview

Interface not integrated; Retrofit Effeckta RS485 interface.

3-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Install the RS485 interface in the inverter

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Installing the RS485 interface
Procedure

► Install the RS485 interface in the inverter in accordance with the interface card installation instructions.

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made data cable (optional extra; not supplied)

or

self-made, shielded 3 wire data cable and terminal block connector.

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

Terminal

► 1

► Pin 2 RS485 A (+)

► 3

► Pin 3 GND

► 4

► Pin 1 RS485 B (-)